Answer Posted / mahantesh kanthi
CORONA EFFECT OCCURS IN O.H CONDUCTOR, WHEN APPLIED 30 KV /
CM, STARTS MAGNETIC FIELD AROUND IT WHICH ENERGISE THE
VELENCY ELECTRONS AROUND IT, ENERGISED ELECTRON GOT
VELOCITY STRIKES THE NEUTRAL ATOMS, CHARGES ITS FREE
ELECTRONS & THE PROCESS GOES ON THEN STARTS INERACTION WITH
THE PARALLEL CONDUCTOR'S SAME PROCESS, MORE CORONA EFFECT
OCCURS WHEN APPLIED VOLTAGE INCREASED MORE THAN 30 KV / CM,
THE EFFECT WILL BE EVEN MORE, WHERE THE CONDUCTOR DURTY &
COVERED WITH DUST, ALSO OCCURS AT ROUGH SURFACE OF THE
CONDUCTOR, LOOKS IN VIOLET COLOUR THAT TO IN NIGHT,HISSING
SOUND OF CORONA CAN BE HEAR BY DISTANCE.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Enlists the applications of sampled data systems?
What is Antipumping Function & If we have C.T how we find the Ratio ?
How to improve fuel cell in a distribution system?
I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.
What is a differential amplifier? Also, explain cmrr.
how the characterstics of control valve being done
WHaT IS THE CONCEPT OF INDUCTION LAMPS IN MODERN LIGHTINGS, and HOW IT WORKS TO EMIT LIGHT ( AS NO ELECTRODES ARE PRESENT ) ?" COULD INDUCTION LAMPS CAUSE INTERFERENCE WITH COMUNICATIONS INTO A STORE USING INDUCTION LIGHTING ? WHAT IS THE BENEFIT OF USING THE LOW FREQENCY INDUCTION LAMP , VERSUS LED , AND VERSUS FLUORESCENT, AND VERSUS ANOTHER KIND OF LIGHTING . THANK yOU MOISES GUINDI
How much weight an electrical engine can pull??
What is the difference between earth fault protection of motor feeder with CBCT and Without CBCT ?
Please provided formula for calculate the cable size from step up transformer to M.V panel, run overhead aluminum cables, total load is 5mega watt, total length 900 feet.
dg earth connect only in the amf panel or not why
defination of transistor controlled series capacitor
What is the BS(British Standard)code for 11kv motor
If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..
HOW TO CALCULATE THE HEAT AND LOAD OF LT-SUBSTATION WHICH CONTAINS 2*1MVA TRANSFORMERS,LT-SWITCH BOARD,MLDB,ACB,BUSBAR,ETC,......?