why we use -ve voltages in vibration prob?

Answer Posted / steve sabin

As a 20-year Bently Nevada employee, and as someone
responsible for answering such questions over the years
within our company as well as externally, allow me to
explain the rather interesting circumstances behind the use
of negative voltages (-24 vdc) for powering eddy current
vibration oscillator/demodulator devices.

The short answer is that when Don Bently worked on making
solid-state versions of the eddy-current measurement system
(it was actually originally designed in the 1930s by GE
engineers using vacuum tubes), he had a choice between
using N-P-N transistors or P-N-P transistors. At the time,
transistors were quite expensive, so he chose the least
expensive of the two: P-N-P (apparently, PNP transistors
they were less expensive to manufacture 50 years ago than
their NPN counterparts).

Because the circuits used PNP transistors, a negative bias
voltage was required rather than a positive bias voltage.
Don chose -18V. This was later changed to -24V to allow
more linear range from the transducer.

At that time, the industrial instrumentation community had
not yet standardized on +24 vdc, and by the time they did,
there were so many Bently Nevada eddy current vibration
sensors installed that changing to +24V rather than -24V
was not greeting with enthusiasm by users. Hence, it has
remained -24V to this day.

This was not a deliberate effort to "be different" or "non-
conformist" on the part of Bently Nevada. It was quite
literally based on which components were the least
expensive when the technology was originally introduced 50-
plus years ago.

Regards,

Steve Sabin
Marketing Communications Manager
Bently Nevada Asset Condition Monitoring
GE Energy Services

Is This Answer Correct ?    24 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the responsibility of an instrument commissioning supervisor

2638


Gas equation

1404


wich is coming the first HAZOP OR SIL

2313


Punj lloyd is coming in our Jadavpur Universtiy campus for campus placement. Please send me some hints about the writtend exam. My email id is subratafriends@gmail.com

2373


If fire would be inside the plant which fire detector is to detected the fire.

1069






What is the use of double seated valve?

731


HOW CREATED LP & HP PRESURES IN DRUM FOR DRUM LEVEL MEASUREMENT!

1432


Which types of quections asked in interview for FORMULATION PLANT (PHARMA)

6215


what is cems analyzer explain with principle and drawing ?

1871


what is output of FOUNDATION FIELD BUS transmitter

1694


What is Alpha & Beta fctors related to Orifice Plate & its relation with flow?

2927


TECHNICAL/ARTITUDE

1717


defination of radial vibration?

1670


what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?

2070


Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?

10398