Whot is the difference between MCB and MCCB.Whot is the
selection critearea for MCCB and MCB for 63 Amp.
Answer Posted / srinivas
MCB MEANS MINIATURE CIRCUIT BREAKER IT IS USED FOR SMALL
QUANTITIES.
MCCB IS MOULDED CASE CIRCUIT BREAKER IT IS USED FOR LARGE
AMOUNT OF POWER.
| Is This Answer Correct ? | 14 Yes | 2 No |
Post New Answer View All Answers
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what is the function of impulse relay
we all know voltage is a force(emf), and the force always devides if 2 or more than2 loads are there but why does the voltage remains same is parallel, it must devide na ???
how electical engineer is related to apsrtc (general) post? if they ask a question in interview as why did u choose this job what shd be answer
why the earth is taken minimum in supplying? wather it the proportional factor to getting work any equipment or a power plant?
Vibromotor 252MV 1/4HP2P..what is mean by 252MV?
could anybody able 2 send me jindal steels previous papers fr electrical steam....pls send 2 my id if possible....sirisha.shaik@gmail.com
How to select circuit breakers rating eg. if i select a circuit breakers of capacity 40 amps DC with operating voltage 28 volts and if i what to use same circuit breakers for 300 Volts DC application what is the current rating of this circuit breakers.
how can i improve the power factor in domestic (230v)
can some one clearly explain why -48 volt DC use in telecom site????
What is the classification of hydro projects based on installed capacity?
Why arc quenching is used in Diode ?
what should be correct gas pressures to be a 1.5 ac unite
How relay works, reverse relay, master relay, os relay, earth fault relay and what is its setting point
A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.