Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why C.T secondary are rated 5A generally?

Answer Posted / puneet kumar

because current is measure by ammeter whose rating is up to
5 amp.(at secondry side of CT - CT is used only to reduce
the level of current at the measurable and safety level)
since we konw that CT has only 1 turn at primary
side becuase current is at higher value, to reducing it we
provide more turns at secondry side.. and this value can
measure by 5 amp. ammeter easily.
In power system, CT is used as protection device
also, which give signal to relay for operate under when
current become more than 5 amp.(at secondry side)

Therefore, CT secondry are rated 5A generally.

Is This Answer Correct ?    0 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT IS IEC? & WHAT IS BENEFIT TO PRODUCT FROM IEC?

2076


y we use neutral,all r told its used to for closed path..k its a just used to closed path,in a transmission line y we put same conductor used n both phase and neutral..if we use less than phase conductor in neutral mean we ll reduce cost its right r wrong..if we use mean any problem occur in transmission line..

1926


What is trip and closing coil in cb? Why need of them

1449


what are the advantages and disadvantages of speed control of 3 phase induction motor by varying frequency explain with drawing

2615


When semiconductor fuse does save thyristor in each cycle of conduction? Why under voltage setting keep less in SPRS and more in DC drive?

2033


why is a power transformer used only occasionally?it is used to step up at generating stations?and that needs to be done all day long !!!!!!!

1817


why do we use 25kv supply for traction purpose?

1853


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2094


Can you explain about pole discrepancy scheme

2132


how to calculate the change over time for star delta starter for different KW motor?

4174


what is the mechanism of operation of brushless dc motor why is it more wexpensive then ordinary permanent magnet motors

1939


What are the basic properties of signal flow graph?

1147


what is thermal resistance of PVC Cable.

1755


what is v/f control in VFD?

1487


TYPE'S OF BREKAR ,WHAT IS TRANSFORMAR & SAFTY. STARTER DOL & STAR DELTA STARTER.

2533