Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the resistance value of our human body?

Answer Posted / baljindra kaur

1000 ohm

Is This Answer Correct ?    4 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the role of power pack in substation protection system?

2746


what is self capacitance of inductor

2468


what are the reasons of CT circuit faulty in busbar protection scheme?

1512


what happened when we supply a dc current in dc motor?? can it worked properly?

2002


Best way to measure the Soil resistance of rocky soil, three probe method and four probe method

1990


What are the site acceptance tests for power cables, DG Sets, LT panels & 30kVA UPS ?

2438


how the inner and outer body is separated in aircrafts?

1156


give single line diagram of D.G distribution form alternator to main L.T panel?

7612


two phases with neutral supply can be taken in 3C X 10 sq.mm cable .

1483


What is Control & Relay Panel? And Remote Control Center?

2267


What do you mean by turns ratio of instrument transformer?

1141


what is the relationship between phase & neutral

2641


how to interlock 3 incomer-ACB,1 buscoupler ACB,... pls answer this question and if possible send me the ckt diagram..haifriends2910@gmail.com

2969


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2197


why motor range is available 22kv,30kv,37kv,45kv and so on? why motor range is not available 21kv,24,25,26,27kv and so on?

2860