What is the difference between MPCB and OLR?
Answer Posted / nithyananthan
hi. the olr and mpcb both are the protecting devices. but
the olr senses the current of winding capacity. means the
maximum current which does not cause the winding
insulation.it always connected in the starter.
but the mpcb sense the over current by means of load. the
phase to phase short, and the dead short are sensed by the mpcb.
| Is This Answer Correct ? | 9 Yes | 3 No |
Post New Answer View All Answers
Why DG set is not installed in Terrace ??
11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??
what happen when increase or decrease size of lamp,light.glass.
hi....I am from india..i have completed my engineering in electrical and electronics field with 58.4% and my IELTS score is 5.5 bands....Recently i received my I-20 in computer and information science from Troy university in Alabama.On 18th i have a visa interview can u please tell me what type of questions i have to answer ??????
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
What is the equivalent circuit of a transformer and its vector diagram?
Why 3 phase induction motor getting supply in body if one of it's phase is cut
ELECTRICAL DRIVES: can a motor load system with passive load torque can have equilibrium speed in second quadrant
what is magnetizing and demagnetizing current in generator and motor?
what is laser diodes?
What is transient response?
Proviiding the Dedicated N earth and individual Body Earths ,Finally these all looped /Now my Question :- will it not harm in case of Transformer Fault current flows in Dediacted N Earthing to Looped Body Earthing.
what is the use of surge suppresser in 33 KV incoming panel. where it must be installed,inseries with incoming cable surge suppresser must be at incoming of the breaker are outgoing of the breaker
What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.
What is nyquist contour?