During Millivolt drop test current leads are applied in the
extreme ends and voltage leads are given just before the
current leads.. what will be the difference if voltage
leads are given in the extreme ends? and why?
Answer Posted / ashoka k sahoo
As we calculate the voltage drop in millivolt drop test the
voltage lead should be always in the current path other
wise it will not be able to calculate the same.
| Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
How to decide the size of the capacitor for a single phase induction motor say 2 HP ??
what is the difference between RMS & TRUE RMS VOLTAGE
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
which motor have relatively high power factor and what is reason for have high pf? 1.capacitor run motor 2.shaded pole motor 3.capacitor start motor 4.split phase motor
operation of diesel generator
WHAT ARE THE CHARACTERISTICS OF AN VOLTAG AMPLIFIER
How to calculate the electrical load for a standard telecom BTS shelter and choose the DG set capacity for the same load?
3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.
How to calculate the efficiency of Turbo Generator(Alternator) in general....?
various transmission tower like .,D tower ,K.C.O tower ,C.C.O tower,K.C.R tower ,C.C.R tower ,H.C.O tower in different tons.
what is the operating time for LBB and how does the LBB relay realise whether cb is opened or not?
in science exhibition how lamp can blink when you clap near the lamp ? thank you
for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?
What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.
acb(AIR CIRCUIT BREAKER)NOT CHARGING AUTO