Answer Posted / farzan danish
earthing resistanc should must be less than 1 ohm
| Is This Answer Correct ? | 10 Yes | 1 No |
Post New Answer View All Answers
what do you mean by type zero control sytem ?Give an practical example of type zero contol sytem?
Iin ESP why positive is grounded ? why not negative ?
What is the basic principal, by which DC voltage level is increased more than the supplied AC voltage during conversion. As upto AC level it is contorrled by firing anlge but after maximum level how is it possible.Please clear picture. OR we have to supply the higher level AC?
if grounding is notdone at regular intervals for long distance transmission, will the load connected at distribution end receive voltage during negativehalf cycle of the sine wave?
limitation of conductor height on ground when we consider EMC
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
I have 4 busbar of 1000 ampere. we use 4 busbar to make 4000 ampere in one phase.my problem is that when we applied 60% load on that then busbar produced high noise.what is the reason of that and how can i minimize that noise.
what is the difference between earthing and unearth
why we not used 11kva as a direct our electrnics component.
list the type of vfd? wich is sutable for heating kiln?
What type of fittings and electrical accessories can be install in radiation area ?
I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?
As you achieve greater success with the company after some years, Will you like to be a share holder in our company?
1.25 kg of hydrogen are burnt with stiochiometric air, the mass of air in kg required is
how did i get the competency certificate as electricle supervisor. iam completed my b.tech.but i dnt have any experince, this certificate is required for applyng ongc mangement trainees. what should i do sir please suggested me