what is purpose of using reactor in substations.

Answer Posted / dilip

Reactor is mainly use to compansate power system in both
underloaded (Inductive)and overloaded(Capacitive) condition

Is This Answer Correct ?    13 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Wt is the function of reactive power? How it generates & consume though resultant is zero?

1456


How much should be the load percentage for 15kva Inverter and Iinut & I output load with Calculations

1583


please send me RRB electrical engineer previous year questions for Sr. Section Engineer

1488


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1492


In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above

1755






What is signal flow graph?

659


explanation of mesh bus bars

1685


how to determine motor size for a fan application?

1789


What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

1588


PLZ EXPLAIN CORONA,SKIN,BIRD PALE,SPAN,SAG Effects of power cable.

1535


how to control the speed to switched reluctance motor

1497


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1658


What will happen if we introduce negative feedback to a control system that uses a positive feedback?

679


what is PDU in transformer?? which company manufacture??

1379


How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.

1622