WHY IN THREE PHASE CABLE 440V CURRENT FLOWS IF IN ONE PHASE
230V CURRENT FLOWS ???

Answer Posted / rameez ajmeri

Actually Voltage is the potential difference...now the
potential difference between two Phases is 440V while the
potential difference between Line and Neutral is
230V...also the Voltage in three phase is given by root 3
into Phase voltage...

Is This Answer Correct ?    14 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In india, according to trade theory above 5 HP motor reqired star delta starter. But we R connect 11 KV motor with 14MW in Direct to line ( With VCB starter combination) Can U Guess, How it is possible ?????

1608


With a phasor diagram show the effect of increasing the field current of a generator supplying a constant real power and connected to a grid system.

1512


A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?

1737


How many sprinklers should be in one pipe line?

1428


what is the transiant condition in alternator? and how it can be prevanted?

1509






why actual valve timing diagram is different than ideal valve timing digram of a 4 stroke engine?

5059


WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.

1445


ht side line to earth voltage

1075


How to reduce the static electricity producing in solvent room? By P.D.Patil BioCon

1581


derive DC RMS value for half wave rectifier?

2716


need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.

1316


list the advantages of RCCB over other circuit breakers?

1269


what clearance required for 4.5 mva dry type transformer?

1631


i karmveer bharti persuing b.tech . plz send me syllabus and name of reference books. for preparation of section eng.

1658


Mention what are the different colors on wires indicates?

761