what is armature reaction?explain in simple words?and what
is its infleunce on dc motor
Answer Posted / aday9
Armature reaction is the interaction between flux set-up by the current carrying armature conductors with the main field flux.The entire energy conversions from mechanical to electrical in the case of generator, and electrical to mechanical in the case of motors takes place only due to this interaction.
| Is This Answer Correct ? | 4 Yes | 6 No |
Post New Answer View All Answers
What do you mean by lighting transformer?
List the time domain specifications.
what is V.L.F. testing of power cable? do you know the voltage ratings, like for what rating and size of cable what rating of V.L.F. testing is used?
How the frame size of a flange mounted AC induction motor is calculated?
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
Dear All, I am new in construction company , my boss ask a question at time of interview , If we have 60MW generation and Single Power Transformer step-up we have. if CMR 50/60MVA , ONAN, ONAF respectively , is it sufficient or not ? for that much power to transfer,
what will happen if i connect 12 volt battery with 24 volt battery charger.
In which working principal temperature transmitter work.explain in detailed.
What shall be the secondary output voltage if the primary winding of a 220/6V, 50 Hz transformer is energized by an 110V, 60 Hz supply?
what is the formula for computing cable tray size & capacity
1.what is the funtion of chiller primary & scondary pumps. 2.what is the use of distribution lines & Types. 3.what is the use the thermal power stations & how much capacity.
what will happen if ac and dc supplies given
Please elaborate th´evenin’s theorem?
what is a power factor?
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain