Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Difference Between Induction Motor & Servo Motor

Answer Posted / rashid khan

induction motor have a high inertia whereas sevo motor have
a low interia due to we stop it at any instant.servo mohave
have a high starting torque and have a capapbility to break
that torque at any instant,whereas induction motor have a
low starting torque and we can not stop it any exact
positio dueho high interia.accuracy of servo motor are more
than induction motor but it is expensive.generally servo
motor are to be use where we required a high starting torue
with small displacement.if the servo motor connect with
servo drive then we need a 24 volt dc spply to execute or
drive.

Is This Answer Correct ?    46 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is there any rule to select the voltage of motor based on KW rating? What is the rating above which lt motor becomes the HT motor?.

1725


what is the effect of un-synchronized power.

2071


DEAR SIR/MADAM,CLEARLY EXPLAIN ABOUT CRAWLING AND COGGING EFFECTS IN INDUCTION MOTOR.

1981


which type of questions asking for solar companies?

1602


who can measure the size of power cable?

2164


What is the earth treantment procedure?

2079


Can we use BS 6651 and BS EN 62305 standards for computer room lightning ptotection in substation?

2257


what is difference between line differential and transformer differential?

1742


Meter p.t. ratio= 3×230/400 , c.t.ratio = 3×1 (2) A what is m.f.

1756


Is it possible to measure the voltage of a battery from a single terminal?

1742


a 100mva,400/200v transformer has leakage impdce of 10% draws a steady state line currentof---------------

1928


how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .

2286


State the methods of improving power factor?

1156


Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV

2174


we use 400/5A ct and 35/roor3KV,/0.1/root3KV,0.1/root3KV pt ratio. What is the multiple factor of this meter.

2013