1.What is the proper definition of power system stability?
2.some times a blue spark is visible in the secondary side
of a distribution transformer at the contact position of
bushings and fuse wire,why?
Answer Posted / t.swaminathan
1.System stability is generally continuos maintenance of
power with proper voltage levels. Mainly it means the GRID
VOLTAGE CONDITION / REFERRED DOWN TO THE 11 KV LEVEL.
SYSTEM IS SAID TO BE STABLE IF PROPER VOLTAGE IS MAINTAINED
WITH RATED FREQUENCY.
IT GETS AFFECTED WHENEVER THERE IS BREAKDOWNS OF
TRANSMISSION LINES/POWER GENERATION.in which case the load
is to be met by lessor power momentarily,till the
generation picks up referred to the lower/higher frequency
due to the breakdown.
2. This is simply because the connection in the LT side of
the transformer is not proper. ( loosened ).
| Is This Answer Correct ? | 2 Yes | 3 No |
Post New Answer View All Answers
What are the different towers used in 132kv transmission line? what are the differences between the P,R,S towers used in 132KV and detailed explanation
technically, what is the reason behind starting the motor star the delta connection .. and what other ways to do this rather than using " star-delta transformer"
what exactly commisioning work does in electrical site work... LT side?..
What is the effect of atmospheric pressure & Temp; on efficiency of motor? Why NGR(Neutral Grounding Resistor) is used in 132/11 KV Transformer & how? What is the use of Auto T/F in Grid Station?
upto how many load can v connect to stabilizer which is used for tv
In the formula : Knee point voltage = Burden X alf / class, Please inform what is alf? regards Shashidhar M.R.
How to calculate phase to phase difference ?
sir iam a 3rd yr eee student.no core company comes for recruitment to our college.my aim is to be placed in l and t.tell me the procedures.
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
hai now i am working as a electrical design engineer in construction field can i get a job in oil and gass field or power plant project as a electrical design engineer?
what are the industrail measures to over ferranti effect? how would the ferranti effect the power system if those remedial mearsure arent taken? how often does this effect occurs in real power system?
How would you calculate power loss in a resistor?
what causes contact chatter when there is no demand on the air conditioning unit?
any body,pls tell me how to done relay coordination ? how to coordinate by TCC curve?how to read the tcc curve?
What are the conditions to be satisfied for parallel operation of dc generators?