What is meant by Active and reactive power?
Answer Posted / kushal
Actually in the transmission line the powerflow takes place.
the complete power in the transmission line is known as
total power which is further divided in two parts i.e.
1.active power or real power or apparant power.
2.reactive power or unreal power.
now their work in the transmission line
what exactly they required for...
1.active power:it controls the frequency balance in the
transmission line.
2.reactive power:it controls the voltage balance in the
transmission line.
what happens basically
Total power is denoted by S = P + Q.
where P=active power
Q=reactive power.
when the resistive power get mixed up with the inductive
power it becomes active power & when resistive power mixed
up with the capacitive power it becomes reactive power.
thats why when the inductive load on the transmission line
becomes more then we have to add capacitive reactance to
compensate it & vice-versa...
| Is This Answer Correct ? | 28 Yes | 5 No |
Post New Answer View All Answers
sent to a site and asked to explain how you would like a twenty seven flour building should be supplied with lighting and sockets plus a water boiler.
what is the setting of locked rotor in HT motor ? (answer expecting in percentage)
Hello everyone, somebody knows what is a "surplice power" ? The hole phrase is: "This rating is appropriate for a generator set paralleled with an infinite bus e.g. a national electrical supply network or grid where the generator set is run at 100% load, 24 hours a day, 365 days a year and any surplice power is exported into the grid" Thanks in advance.
why the carbon brushes are broken in srim while the motor runningtime
hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible
hello!my name is sheikh iam preparing for indian engineering servieces,please send me the old question papers..to sheikhshaazforjobs@gmail.com
What is the difference between multimeter
A generating system will have a total capacity of 300 MW. Find the probable forced outage when the capacity is supplied by two 150 MW units. The operating probability of all units is P=0.98 and forced outage probability rate Q =0.02 .
What is phase cross over frequency?
explain working principle of earth leakage relay
Explain the difference between verilog task and verilog function?
can u please mail me the syllabus for GET exam for damodar valley corporation?
what is solkor relay and which condition it will act?
l&t switch FN 63 handle position can we change
how to put cable sizing and cable glands size for respective cable & Cable Lug size in a DB sectors???