Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is meant by knee point voltage?

Answer Posted / parveen

Knee point voltage is calculated for Current transformers
and is very important factor to choose a CT. its the
voltage at which a CT gets saturated

Is This Answer Correct ?    11 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What happens if we connect a single phase energy meter in reverse polarity.

2363


can we synchronize star system generators with delta system generators?

2060


why the perameters of secondary circuit are more important then that of the primary circuit of induction motor?

1912


I have doubt that the supply HZ (very low or high than rated ) may affect the power factor. is it true. ?

1670


show the single line diagram of star delta starter with single phase preventer

4641


what is acceptable leakage current for 33kv cable while doing high voltage test for cable? how to calaulate the leakage current for 33kv or any rated cable?

4036


What is the temperature PROFILE OF A FLUID W. R. T. Distance from a sphere to which it is IN CONTACT which is at constant temp.?

2064


WHAT CAUSED THRESHOLD VOLTAGE TO EXIST?

4071


during installation time of transformer and alternator which points we have to observed?

1950


how many electricity poles are there and what are the names and their sizes.

1920


Initially, when the input is not equal to the output — what type of response is this?

1064


we have provided 30 nos. relay contacts in panel.I want to know how do we do the numbering for the relay contacts as per any applicable standards

2009


What is the difference between rulling span and wind span of of an Over Head Transmission Line?

2325


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2034


what is meant by tranformer impedance?

2605