why near the transformers, the Jelly(small white colored
rocks)are poured.and what are conditions for that?
Answer Posted / qwerty
Because the sound came from trafo attracts snakes.and the
rocks make scratch on the snake,so to avoid snakes near
trafo we put it all around.
| Is This Answer Correct ? | 3 Yes | 5 No |
Post New Answer View All Answers
in ring main system we use the isolater b/w transfer bus and main bus if we r not use isolatar than wat will be the effect in our sys.
how to find Harmonics and types as per the equipemnts
why different series of vfds (like allenbradley)are used in industry ?
What is the limitation of kirchoffs law?
What is reverse power relay?
What is transister define the transister ammiter ,base, colector.
What is state space method ? Why its used ? Can it applicable on linear, non-linear, 1st order, higher order, homogeneous, non-homogeneous, open-loop , closed loops , stable & unstable systems ?
if two transformers are placed parallel & both have fault impedance of 50KA will it increase or decrease show example?
what do you mean by type zero control sytem ?Give an practical example of type zero contol sytem?
What is the difference between amorphous core transformer and CRGO core transformer?.
Q) Write VBscript code along with QTPscript code in QTP tool for below scenario 1. Launch yahoo site(i know) 2. Do loogin(i know) 3.Click inbox link(i know) 4.Go to every page of mail box and count no.of read mails and no.of unread mails(i know) 5.Store page numbers, read mail count and unread mail count in a new excel file sheet 6.Create 10 types of graphs on that data 7.Do logout and close site(i know) 8.Save new excel files with graph
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
Difference between shunt, PMG and AREP excitation. Which is the most reliable between PMG and AREP.
How can we find the breaking capacity of a Load breaker switch (LBS) fed from 11 kv supply??ex:50KA, 26kA etc???detailed step vice answer pls.
What is Plank's Law?