what is derating?, why it is neccesary, it is same for all
means for drives, motors,and cables.
Answer Posted / mrinal
The current currying of cables will change depending upon
the site temperature (location of site), type of run(it
will run through DUCT, TRENCH, BURRIED ect.), number of
tray, depth of trench, distance between cables. Considering
this condition actual current currying capacity of cable
reduce than current currying capacity (which given to cable
cataloge) this is called deraing.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
what is cause of static electricity? I experience shock when i touch metal equipment in a room ,furher check shows earth leakage showing 80ma at the DB near to the 400 MCCB?
what is vtg limit of earth and neutral at transformer side?
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632
Explain Creepage Distance of Insulator
what is deffrence between squirral cage and wound rotor in IM?
which pump used in WTP explain the function of VFD how to dtermine capacitorbank of capacity one plant
Give accurate definitions for these electric terms: Inductor Inductance Inductive Induction Reactance Reactive Esam Baraka ٢١ ساعة
How much of the total hydro power potential has been exploited so far in india?
what r the checklist while installing 500 kva transformer
what is the difference between 2 way and 4 pole selector switch???
what is automatic voltage regulator?we can control the vlotage by using fuzzy controller in matlab?why we go for fuzzy?
i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value
how can we understand that where we have to use ac or dc coil for solenoid valve and why?what is the different between coil of ac and dc explain please.
1.why are not using acb 33kv ht side? is there any problem 2.what is difference between acb,vcb,sf6 breackers? 3.what is the function of invertor and convertor in ups?