Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is meant by regenerative braking?

Answer Posted / dipak patil

This term basicly consert with traction moters and it is
one of the method used for braking traction locomotive. In
regenerative braking the DC moter is made to work as DC
generator by reversing the field winding without
disconnecting the motor from supply. this result into
braking action and motor slows down.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is there a possibility to use such a treshold voltage for the NMOS part of a CMOS circuit that during the switching it will start conducting only after the PMOS part will be already closed, by this eliminating the leakedge current? Please note, I'm not asking about the well bias in standby mode, but about the "antileakedge" measures during normal operation.

2049


What is error of a measurement?

1197


pls tell me function of closing coil of A.C.B.

3366


WHAT IS IM (INDEX OF MOUNTING )IN MOTORS

2020


how will reduce the voltage. if 12volt/250ma transformer toreduce 6 volt

1949


Single line digram for 11 kV to distribution use go,la and do

1792


A 3-phase IM is supplied from 50 Hz system. It runs at speed of 1440 rpm and slip equal to 4 %. Calculate number of pole pairs. A 1 B 6 C 2 D 3

2007


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1574


1)What is a Triode? What are its uses? 2) What is a Triac? 3) What is a Thyristor?

2617


tell me about roaster switch .& what is the function in transmission & distribution?

2645


how can i determine the KVA/MVA rating of transformer precisely?? is there any standard test?????

2382


how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)

2349


wish of these transformer uses oil?

1606


Explain the process of commutation in a dc machine.

1025


i need previous entrence exam papers of nhpc.

2816