what is the PH value for boiler water.

Answer Posted / priyank sharma

raw water ph value=7.5-8.5(with hardness & sulphate)
feed water ph value= 7.0-8.0(without hardness & sulphate)
condensate water ph value=5.5-6.5

Is This Answer Correct ?    9 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why screw compressor use for ammonia compression?

1493


Do you have any idea on recombinant protein expression?

600


In Galvonised iron and stainsteel pipes, in which pipe friction losses will more and why ?

2110


I would like to know how to size a partial combustion reactor processing methane and oxygen, as a function of the flowrate and of the pressure.

560


Are some heat transfer services more prone to tube vibration that others for a shell and tube exchanger?

672






What is a good source of surfactant information on the internet?

719


MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)

1823


Is there any way to repair a valve that is passing leaking internally without taking our process offline?

724


Name some factors to consider when trying choosing between a dry screw compressor and an oil-flooded screw compressor?

556


What chemical is used to expand air bags in such a short amount of time?

671


What is cathodic protection, how it works in Turbine condensers ?

2432


What is the most common carrier gas used in pneumatic conveying?

730


What is the definition of 'good' cooling tower water?

552


How can wet carbon dioxide be responsible for a corrosion problem in iron-containing metals?

624


What is the angle of repose and what are its applications in the chemical industry?

627