IN WHICH MODE THE TRANSFORMER WILL GET A MAXIMUM OUT PUT
VOLTAGE. ASKED FOR POWER GRID EXAMINATION
STAT-STAR,STAR-DELTA,DELTA-STAR,DELTA-DELTA
Answer Posted / srinu
Delta-Y
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
Why is the starting current high in dc motor?
Hello sir, pls send me hpcl technical test papers .i am. Appearing for the exam.
what is the minimum requirement gigaohms for the insulation test using 5kv in 300mm xlpe cable
what will happen if multimeter(selector switch at DC voltage) and terminal at current is connected to DC supply?
WHaT IS THE CONCEPT OF INDUCTION LAMPS IN MODERN LIGHTINGS, and HOW IT WORKS TO EMIT LIGHT ( AS NO ELECTRODES ARE PRESENT ) ?" COULD INDUCTION LAMPS CAUSE INTERFERENCE WITH COMUNICATIONS INTO A STORE USING INDUCTION LIGHTING ? WHAT IS THE BENEFIT OF USING THE LOW FREQENCY INDUCTION LAMP , VERSUS LED , AND VERSUS FLUORESCENT, AND VERSUS ANOTHER KIND OF LIGHTING . THANK yOU MOISES GUINDI
What are the weight of 800KV DA,DB and DC type tower ?
in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com
i want to run 11kv star connected motor in 6.6kv with delta connected throught inverter, is it possible?
why would the rotor rotate at sub synchronous speed against the direction of rotating flux when d rotor of 3 phase IM is connected to 3 phase balanced supply and the stator windings are shortcircuited ??
some time we open engine breaker 8.0 MW load but plant not trip. and another time engine open 4.0 MW load engine trip why? individually engine breaker open & individually emergency stop why difference?
What is open loop and control loop systems?
what is the transformer rush current?
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
How many types of oil using in H/T & L/T Oil Circuit Breakers. need Explenation ?
if 3400kw slipring motor rotor shorting done and motor started on mv drive ,what will be the rotor shoring current