Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the generator efficiency is greator than motor?

Answer Posted / gunasekaran

for generator i/p is not constant it is varriable but for
motor input power is constant.

Is This Answer Correct ?    2 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2193


Can we use 230VAC, 63A MCB for 120VAC, 63A supplied heaters load?

1459


WHAT IS MOBILE SUB-STATION? & REALLY BENEFIT IN INDIA

2057


I need a formula to calculate the size of cable as per load but in the terms of length. Please Reply me as i search lot of sites but i did not get the answer.

2048


Define what is power quality meter ?

1235


with out colour codeing on conductor how can be find what is r,what is b,what is y phases.....

1932


WHY THREE PHESE SYSTEM VOLTAGE APPLIED IN 440 VOLT

2315


How many sprinklers should be in one pipe line?

1944


what is the minimum requirement gigaohms for the insulation test using 5kv in 300mm xlpe cable

1959


WHAT IS MEANT BY DERATING OF THYRISTOR?

2947


We are designer please help me calculate the size of 11kv cables from step up transformer to M.V panel, total load is 5 mega watt distance 900 feet (used aluminum type cables) please provided formula for calculate the cable with example.

1627


What is difference between Over Current & Earth Fault protection?

2423


why current flow to the opposite direction of flow of electrons???????????

2137


What is the pro & con of having 11kv & 33kv incoming, and what is the adv & disadv. of converting from 11kv to 33kv.

2807


in conventional fan regulators how the current varies with speed?

1976