Answer Posted / iamdon
The electric drive which uses variable voltage and variable
frequency for its operation and control is called VVVF
drives.With the technology improvement in the realm of
power electronics now it is more easy to work with VVVF.
Cycloconverters are employed to obtain variable frequency
up to 400Hz.
VVVF find applications in railways traction,airplane etc.
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
How is the speed of a DC shunt motor related to the armature current?
what is meant by twilight switches 7 where its applicable ?
where is the need for short circuit test for 3 see is required and why? can you explain in brief with application
What are the specifications for conducting earth leakage test as per IEC standard?
Can u explain : what is supply for train (whether a,c or d.c ).I know that supply is 25000v a.c .But there is rumour that supply is D.C. And also explain how lights and fans inside the trains are working ,and what type of motors are used in trains whether D.C motors or induction motors .If d.c motor, how it gets supply.If traction motors are used then what are traction motors and its functions and how it differs from other motors and also explain about locomotive . y d.c series motor in train.train wheels r driven by D.C shunt motor ,at what voltage,and at what speed. please reply..............
3ph motor running with unequal kw and different pf what are the reasons
What happens if the negative to earth voltage is greater than positive to earth voltage in the battery of substation?
700KW 6.6KV slip ring induction motor to use VFD to control the speed
Why do power lines not short out when they fall into water?
why connecting surge unit in contactor coil
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
How one may guess the direction from which the distribution line is incoming if there is no pole plate on poles?
In synchronization circuit what is the function of Interposing voltage transformer(IVT)and Reverse voltage transformer(RVT)
why we use single core 630mm2 cable for transformer secondary side
how to know the diffrential relay setting of 06mva step- down (delta-star)transformer?