How the output,losses and temperature of machines varies
with linear dimension?
Answer Posted / iamdon
When the linear dimension of a machine is varied by x times,
its output is varied by x*x*x*x times
its loss(Fe and Cu each) is varied by x*x*x times and
its temperature is varied by x times.
provided rest parameters are not varying.
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 2 Yes | 4 No |
Post New Answer View All Answers
i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value
Graphs of measuring power and speed on dc motor
What is accuracy of a measurement?
Name the component u would expect to find in a switchgear assembly?
My load is 1635 KW. & current pf is 0.884, I have to improve it for 0.99.Please suggest what KVAR value is needed?
I have 2 KW electric water heater.I am gonna use it in controlling water temp.so I needed to increase or decrease the heating capacity.is there any electrical-electronic circuit for varying the resistance & so current?
i have attended the interview on 4th June,08 at Kolkata in IOCL, can anybody tell me what is its result
Hello seniors m an engineering student in 3rd yr..i want to know what are the software course in electrical field?i wanted to do certification course but i dont know much about the course?..Regards
At the starting of dc motor and syn.motor and induction motor high current flowing through the winding. Due to this the windings burnt out. To avoid this different types of starters are used. But incase of transformer what Will be used (At starting no emf is induced in the primary winding)?
in control panel, how can i measuring the distance between one bus bar to another bus bar. then now only for bus bar. in mpcb and contactor also. that means one mpcb to another mpcb how much distance? how can i calculate that.
what is the formula to calculate voltage drop/loss on 66KV Transmission Line?
I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.
Do any one know exacatly when the results for NHPC held on 8th march 09 for engineering trainees will be released ?. if so please post it, i'm eager to know it.
- two pumps must work with them at the same time but if the first pump start the second pump must delayed for some time to start also , with motor rated power = 90 KW and rated voltage = 380 V and rated power factor = 0.85 lag please draw the power and control circuit for it and determine all circuit components parameters that you use it
what will happen if frequency is below 50 hz?