Why different values of B’s (magnetic flux density) are
chosen for DC machines and Induction Motors?
Answer Posted / iamdon
Induction Motors are designed for COMPARATIVELY LOW VALUE
OF B.Because if we select higher value of B,the magnetizing
current requirement for establishing the working flux in
the air gap will became high.This reduces the power factor.
This condition is undesirable hence must be avoided.
DC machines are designed for COMPARATIVELY HIGH VALUE OF B.
Because if we select lower value of B,the amount of force
developed will became small.Since there are large spaces
available on poles,so we have no difficulty in putting
extra number of turns on it for getting higher value of B.
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is the maximum percentage voltage drop (vd%)for a motor control center
WHAT IS DEAD END IN PROTECTION?
what happened when we supply a dc current in dc motor?? can it worked properly?
why magnetising curve not start with zero voltage?
What is an order of a system.
Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks
At what speed an electric car can run with 2 HP motor of weighing 400 kg?
What is the rating factor for copper cable ( Specific value according to the type of laying ) & the voltage drop?
what is reactive power?, why its measured in VA ? is it transient behavior of system?
how much winding resistance of 0.75kw to 12.5kw 3ph sqwiralcage induction motor?
what is earth-fault?when it occurs? to check where it occurs what type of test should we do?
Why reactive power is needed in a power system? How is it being absorbed or delivered by alternators? For reactive power control we are changing excitation but reactive power absorbing or delivering related to stator. How these two are interlinked? i want a detailed explanation with necessary expressions and figures?
EXPLAIN THE TERMS "INTEREST AND DEPRECIATION" AS APPLIED TO ECONOMICS OF POWER GENERATION.
What is difference and reason b/w -48V BTS system and 24 V BTS system. Plzzzzzzzzz tel me.
How do we calculate over and under frequency tolerance from generator data?