Why different values of B’s (magnetic flux density) are
chosen for DC machines and Induction Motors?
Answer Posted / iamdon
Induction Motors are designed for COMPARATIVELY LOW VALUE
OF B.Because if we select higher value of B,the magnetizing
current requirement for establishing the working flux in
the air gap will became high.This reduces the power factor.
This condition is undesirable hence must be avoided.
DC machines are designed for COMPARATIVELY HIGH VALUE OF B.
Because if we select lower value of B,the amount of force
developed will became small.Since there are large spaces
available on poles,so we have no difficulty in putting
extra number of turns on it for getting higher value of B.
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
neutral earth resistance testing is it possible for transformer while in load condition
please give some hindalco placement papers for written exam
IF ANYONE HAVE ANY QUESTION ASK ME AT MY MAIL anmol.bhardwaj5@gmail.com
a governer in an Ic engine controls the
Metal covered multiconductor cables shall employ a marker tape located within the cable running for its complete length in lieu of cable surface marking. Is it true or false?
What do you mean by lighting transformer?
What is the resistance of the field winding of a d.c. Shunt generator kept low?
What does quality factor depend on in resonance?
What will happen if the d.c. Shunt motor opened accidentally running on no-load has its shunt field winding?
what will happen if synchronous machine rotor fed from single phase ac supply
What is the difference between Droop vs Isoch Control?
Which level of the Transformer oil got dielectric strengh? And why?
what is the vvvf in the dumbwaiter?? or lift. what is the actual process?/
What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.
How Diesel Generator start ?