Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the efficiency of the dc machine is high ,when it is
operated as a generator?

Answer Posted / guest

Effiiency of any machine is defined as the ratio of output
to the output.
Efficiency=(O/P)/(I/P)

MATHEMATICAL PROOF

Since electrical quantities are easier to measure in
comparison to mechanical quantities.
So in the determination of efficiency of DC machines,
we first find electrical quantities(input or output)and
subsequently find mechanical quantities(output or input)by
subtracting or adding the losses.

Efficiency of Generator=Output/input=(V*I)/(V*I+loss)
Efficiency of Motor = Output/input=(V*I-loss)/(V*I)

As long as machine is same, the rating and losses are not
going to change.
Clearly the ratio of above two equation is greater than 1
meaning there by efficiency of generator is greater than
motor.

PHYSICAL CIRCUIT PROOF

If we look into the circuit model,In case of generator back
emf causes less amount of current to flow through the
armature.So electrical losses(Cu loss) are less.Electrical
losses are function of current
In case of motor counter torque is produced so speed of
motor is less.So rotatinal loss(Core and friction) is
less.Rotational losses are function of speed.

Since loss:electrical loss > Mechanical loss.
So efficiency:Generator > Motor

Author:arbelectbit@yahoo.com

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

previous year paper of ntpc bhel for degree in electrical enng

3269


why the starting voltage drop in a cable needs to be limited?what is percentage of the voltage drop allowed during starting?

1887


how braking & making capacity of circuit breaker is calculated?

2045


Draw a block diagramof Three UPS systems connected in Parallel mode?

2217


what r substations?what r there work?why voltages r incresed and then reduced during distribution of power

1990


what is size of 3phase 4wire cable to be used for 11 ton ductable A.C and how to calculate cable size for different load

4081


What are the relays in ACB and VCB

2313


What is the reason behind current flow(20 A) in amain earth cable of an SMDB? Is cuurent flow(45A etc) through a neutral cable acceptable?

2036


What are the no-load losses for the 11000/415V transformer with the following rated capacity? 1.1500 kVA 2. 2000 kVA 3. 2500 kVA 4. 3000 kVA

1820


what shall be no load voltage of 132/33 kV transformer ? is it 33 kv of 34.5 kV

2243


How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).

2218


How delta connection in the primary of distribution transformer reduces harmonics?how delta connections reduces harmonics?Please answer me...Hope that question is correct.

2286


area control error

1786


What is warm / cold start of HT motors. How many warm start & cold start are possible in a day?

2103


What are the operation carried out in thermal power station?

1124