Answer Posted / iamdon
A pulse transformer is a transformer that is designed for
transmitting RECTANGULAR ELECTRICAL PULSES(pulses with fast
rise and fall times) of a relatively CONSTANT AMPLITUDE. A
Pulse transformers by definition have a duty cycle of less
than 0.5.
Small power versions are used in digital logic and
telecommunications circuits.
Medium-sized power versions are used in power-control
circuits such as camera flash controllers.
Larger power versions are used in the electrical power
distribution system.
To minimise distortion of the pulse shape,a pulse
transformer needs to have
1)Low values of leakage inductance and distributed
capacitance.
2)High insulation resistance and high breakdown voltage.
3)Good transient response.
| Is This Answer Correct ? | 11 Yes | 0 No |
Post New Answer View All Answers
Why do we avoid electrical conduits in floors at apartments?
Witch do depand of Power factor and theory of power factor?
Why syn. Generators are used for the production of electricity?
What do you mean by power transformer?
What is the most essential condition for the voltage build up for a d.c. Shunt generator?
33kv substation lay out details & line to line & line to earth measurements
IN induction motor pf is increased using capacitors.what will be the effect on motor and system when very large capacitor is accidently installed and pf goes leading.
How many types of circuit loads are there in a common electrical circuit?
what is the difference between transformer,converter and transducer
In parallel operation time both NGR’s close or not close if both close what will happen
State how to produce a constant rotating field by application of alternating currents to stator armature of a three-phase squirrel-cage induction motor
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
what is a speed of rotor when we give supply to stator of 50hz and as well as rotor of 60hz of an induction motor?????
what is the use of Auto re-closer?
How to calculate flow of water delivered by pump when pressure & size of pipe line is given