A 2D array X(7,9) is stored linearly column wise in a
computers memory.Each element requires 4 bytes for the
storage of the value.If the first byte address of X(1,1) is
3000,what could be the last byte adress of X(5,8)?

Answer Posted / a.divya

no of bytes=4
column size=9
address of the first byte =3000
last byte of address x(8,5)=3000+4(9(8-1)+(5-1))=3268

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the difference between earth leakage and earth fault?

1736


in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply

1559


Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

1552


which book to refer in electrical engineering for iocl exam & which book for general english.

1759


How to do bus bar short circuit calculation for 230KV/11kv, 60 MVA Substation?

4258






What is meant by load angle of an alternator? Upon what factors does the load angle depend?

2557


Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT

2112


What are the types of windings present in the ceiling fan? What winding will be effective first when we started the fan?What are the resistance and inductance ratios comparatively at the initial speed and full speed of the fan?

2440


how to calculate the earth fault current

1955


There is air in a room . the top and bottom of the room are at constant temp. T1 and T2. DRAW THE temp profiles if a. T1 greater than T2 b. T1 less than T2

1420


mention hazard experienced during installation

1526


i have been tasked with a design of protection, metering and control(PMC) relay panel extension to accommodate all PMC relays.There is an already existing panel where this one will be built.What are the design aspects for this kind of project? thank you.

1596


What is the disadventage of gland earthing(power cable) if any. ?

1566


What is depreciation factor?

1764


What is the Temperature to be set in Thermostat provided in Marshalling box of the Transformer / Motor.

2530