Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

can i get model question papers of mahagenco exam?

Answer Posted / sagar saraje

9

Is This Answer Correct ?    6 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why orfice is not used for main steam flow calculation

2109


TECHNICAL/ARTITUDE

2220


If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?

2072


how many type of plug are used in pneumatic control valve,name them.

5403


why using negative supply for bentley nevada vibration system ?

2128


what is the calibration procedure for magnetic flow meter @ onsite

1638


the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)

2049


Hi Friends i need Electronics&Instrumentation Engg question papers for BARC written test by coming 20th May 2008 pls post ur use full info to kkumarei@gmail.com. Or for suggestions pls give one missed call to 9962122264

1939


I have got a call of IOCL interview for projects having 2yrs experience. What sort of questions should I expect in the interview?

2059


WHY THE DEGREE OF VALVE PLUG AND VALVE SEAT IS SLIGTLY DIFFERENT I CONTROL VALVE TRIM DESIGN

1973


dear sir we have insatlled positioner model no.sipart PS2 make Siemens at our control valves . now problem is if we want to increase the response of valve opening speedy /fast. what parameters do we change for positioner ? any idea. please guide us.

1869


Why is it necessary to use compensation leg to measure the liquid level in a closed or pressurized tank?

2435


pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)

2240


what is sliding spool valves?

2220


why direct mounted pressure transmitters is always installed with DBB ( double bleed block) valve in process line or top of the tanks ?

2033