Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the working principle of ceiling fan?

Answer Posted / nilesh vyas

The celing fan motor works on principle of single phase
induction motor using capacitor.
Working of capacitor start motor: The stator consists of
the main winding and a starting winding (auxiliary). The
starting winding is connected in parallel with the main
winding and is placed physically at right angles to it. A
90-degree electrical phase difference between the two
windings is obtained by connecting the auxiliary winding in
series with a capacitor and starting switch. When the motor
is first energized, the starting switch is closed. This
places the capacitor in series with the auxiliary winding.
The capacitor is of such value that the auxiliary circuit
is effectively a resistive-capacitive circuit (referred to
as capacitive reactance and expressed as XC). In this
circuit the current leads the line voltage by about 45°
(because XC about equals R). The main winding has enough
resistance-inductance (referred to as inductive reactance
and expressed as XL) to cause the current to lag the line
voltage by about 45° (because XL about equals R). The
currents in each winding are therefore 90° out of phase -
so are the magnetic fields that are generated. The effect
is that the two windings act like a two-phase stator and
produce the rotating field required to start the motor.
When nearly full speed is obtained, a centrifugal device
(the starting switch) cuts out the starting winding. The
motor then runs as a plain single-phase induction motor.
Since the auxiliary winding is only a light winding, the
motor does not develop sufficient torque to start heavy
loads. Split-phase motors, therefore, come only in small
sizes.

Is This Answer Correct ?    400 Yes 62 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

STATE WORKING OF VACCUM CIRCUIT BRAKER?

1868


At what speed an electric car can run with 2 HP motor of weighing 400 kg?

1768


If Neutral Grounding Resistor (GR) failed/shorted. Is it repairable.

1555


i m electrical diploma holder i want to do plc $ Scada some body tell me which insitute is best for me near chandigarh

3035


HOW WE CHOOSE EARTH'S POTENTIAL AS ZERO V?

2001


How to design the NGR Resistance

2013


Does outdoor isolator loose connection cause short circuit current in that circuit? if yes then how ??

1657


can a 150 kva 3 phase 440v/230V delta-wye step down transformer can be use as step up transfoermer with connected loads at 440v side?

1676


What is the instrument to check the rotating diode fuse of alternator in running conditions?

2422


What will be the fault current of any system when its generation is 10% of BASE generation( FUll Load )?Will is 10% or the same as full base calculation?

1858


An ISP is granted a block of addresses starting with 150.80.0.0/16. The ISP wants to distribute these blocks to 2600 customers as follows. a) 200 medium size businesses; each needs 16 addresses b) 400 small businesses; each needs 8 addresses c) 2000 households; each needs 4 addresses Design the subblocks and give the slash notation for each subblock. Find out how many addresses are still available after these allocations.

7614


What is slip in an induction motor?

1085


what is the circulate the diesel in DG in side pls tell parts name and picture with circulate the diesel

1936


What is the universal motor?

1055


How to discuss the phase shift of transformer considering open delta?

1400