Can the field winding in synchronous machines be placed on
stator?What is the limitation of such arrangement?
Answer Posted / iamdon
Generally the field winding is placed on rotor but it can
be placed on stator, without loss of generality however
such arrangement has limiataions.
Rotating armature type synchronous machines:
DC Field winding is placed on stator where as AC armature
winding is placed on rotor.The electrical input(in case of
motor)and output(in case of alternator)is supplied to or
taken from rotating armature respectively by means of
brush.The brush cann't be employed satisfactorly for large
ratings.So this arrangement is lmited for small rated
machines only.
Rotating field type synchronous machines:
DC Field winding is placed on rotor where as AC armature
winding is placed on stator.The electrical input(in case of
motor)and output(in case of alternator)is supplied to or
taken from stationary armature respectively.This
arrangement is suitable for large rating because it is
relatively easier to design insulation for stationary
armatrure as compared to rotating armature.
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
what is conductor constant of raccun conductor
can i able to get bhel previous exam question paper?
Dear sir, I have completed DECE in the year 1995. I have work experience in HT and LT LINE more than five years. Now i am doing BE in EEE from rajasthan university. After completion of BE,can i apply "C" Licence sir? Please reply.
how we can do the insulation on secondary of ct explain and so that tan delta will within limit
For small size, high frequency coils, the most common core material is- a. )Air b. )Ferrite c.) Powdered ion d.) Steel
What is phenomenon of electromagnetic induction and how it works?
what is solkor relay and which condition it will act?
Write down the name of 2 lady Bir Pratin of Bangladesh
how to measure the transformer resistance values(dyn11)?and howmuch the minimum value?
Is a direct shorth ciruit on a branch MCCB in a Low Voltage Switchboard a correct means of tesing the performance for discrimination?
Draw a SLD for main panel for school having connected load of 1200kw and emergency generator 200kw.also show the increase of additional load of chiller 225kw in the lv panel indicating meter postion size of transformer ,cables and capacitor bank.
How to see the inductance in a transmission lines
what does vector group Dyn11 tell us? also tell me how will u differentiate between phase lead and phase lag thru this vector group
does the Trivector Meter of three phase automatically takes care of the low power factor and gives the reading accordigly or it does not take care of the Power factor while giving the readings please explain
Cb closed condition if there is a tcs fail whether cb will trip or not