Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why all voltage levels are the multiples of 11KV?

Answer Posted / shariff

It is just the standard being maintained by all the transmission utilities, with form factor 1.11, voltage not even multiple of 11 is being under use, like 132kV,400kV etc, if this old standard is changed then it should be changed all over, from generating to distribution level, which is not possible in practical, hence the same std being maintained.

Is This Answer Correct ?    4 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

EXPLAIN THE TERMS "INTEREST AND DEPRECIATION" AS APPLIED TO ECONOMICS OF POWER GENERATION.

2326


The capacitive reactance of a capacitor of 1/(2(PI)) F at 10^3 H is

1853


How do u analyse protection fault when vcb tripping on load

1657


Pls tell me whether we can use EN3A material for shafts of Permanent magnet alternator.What will be the effect of magnetic and nonmagnetic material for shafts on magnetic properties of PM rotor .

3528


What should be the height of basement according to NBCC code?

2208


Generation of voltage for each phase are same of a turbogenerator.Although the short circuit current flow when two phase of turbogenerator are shorted(where current can't flow without potential difference),why?

2123


What is the formula to calculate the size of Aluminium and copper cable?

1964


Dg pf .71 i am improve pf 0.80 what capacitor connected in dg how?

1683


How can I known multiplying factor .without multiplying table

1800


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1891


what is Fan Control Cubicle

2489


what is the difference between Power and Distribution transformers ?

2159


how slip power recovery system work

3031


which fault is severe and why?between lll fault and lllg fault which fault is severe and y?

2510


Name the types of motors used in vacuum cleaners, phonographic appliances, vending machines,refrigerators, rolling mills, lathes, power factor improvement and cranes.

1156