Why consumers are charged based on Kwh basis why not on
Kvah basis.
Answer Posted / mahavir jagdev
They can be charged in Kvah only in case of DC transmision. In AC transmission due to the inductive or capacitive load the power factor comes into play, hence the effective metering is done on Kwh basis. Infact the energy company instruct the consumer whow has a lot of inductive load (motors) to put capacitor banks to keep the power factor within 0.85 region for lower powerline losses.
| Is This Answer Correct ? | 10 Yes | 7 No |
Post New Answer View All Answers
y we use neutral,all r told its used to for closed path..k its a just used to closed path,in a transmission line y we put same conductor used n both phase and neutral..if we use less than phase conductor in neutral mean we ll reduce cost its right r wrong..if we use mean any problem occur in transmission line..
Discuss about gear cutting machines.
How to calculate Temp from Resister from PT100 equation,
An ELHNC 80amp 240v 30mA RCD is tripping periodically, every 30 - 180 seconds is it safe to disconnect the protection circuit?
What is distance between electrical panel to land ?
state the working of discharge lamp?
IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating
do we use neutral grounding for resistive balanced load? if we use what happen?
describe the A.C. Generator Testing procedure
what are the major & minor faults that occur in an inverter and in UPS ? And how to repair and resolve them ?
Why generation voltage in thermal power plant is between 11kv to 33kv?
What is 100% protection of generator? Why 100% is not used but 95% is generally used?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
What are the no-load losses for the 11000/415V transformer with the following rated capacity? 1.1500 kVA 2. 2000 kVA 3. 2500 kVA 4. 3000 kVA