What is the Operating Powerfactor of UPS??? Why??

Answer Posted / ssreenu207

Operating power factor of UPS depends on load which is
connected to the UPS and there is perticular operating
power factor of UPS.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???

1419


What is the formula to calculate the no load current of a single & three phase induction motor

1765


What are the types of power in electrical power?

716


Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

1558


1. What is maximum permissible distance between smoke detectors ? 2. How do we decide number of smoke detectors required in a large office, warehouse, hall etc ? 3. What should be maximum height of smoke detectors ? 4. Where do we use heat detector, optical smoke detector, temperature sensitive detector ?

2377






HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.

1446


What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

1579


please anybody help me to find out the BHEL trainee Exam previous year questions papers . if u ve pls. send it to surekhared@gmail.com

1504


why moisture formation found in XLPE Armoured cable outer sheath

1331


what is the eight bit unit?

1962


Electrical 'C' license full abbreviation , and full form

1327


how the characterstics of control valve being done

1462


What is the difference between isolators and electrical circuit breakers? What is bus-bar?

672


HOW TO SELECT THE COPPER CABLE SIZES OF MOTORS,TRANSFORMERS?

1559


How many wall/floor flange will i use in bus duct system if we have in our design a 35th floor building.

1038