Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what will happen if dc machine are supplied by ac source??

Answer Posted / biswa.biswa2010

only one time on this is used in dc series motor.dc series
motor is slow.

Is This Answer Correct ?    1 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformer 

1788


Why we find the sensitivity for the CT's to check?

1841


we have amp, voltage, kw, length detail then how to calculte copper & alluminium size of conductor of 3-phase induction motor

1441


what is the difference between RMS & TRUE RMS VOLTAGE

2921


while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends

2843


What are the effects of electrical faults?

1014


How seriving & testing of the HT & LT breakers are done. What are the standard Ir values on which we can come to know the test is passed or failed?

2016


whether fibre optic cable in high voltage earth conductor is used for protection circuits

1601


why zero sequence impedance measurement is not applicable for single phase GT

2182


What is transient Phenomenon?

2229


11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?

1651


what will happen reduce the transformer voltage from 415v to 406v, is it save the energy,? are this methodis good to reduce the energy.?

1504


Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.

2341


What are reasond for high wattage in single phase induction motors

1869


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1981