Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How can we reduce the reactive power consumption of your
12.5 MVA power transformer.

Answer Posted / manish yadav

basically reactive power consumption is depend upon the
load pf.. as Q=kw*sin@ ...n so make an arrangement such
that capacitor is connected across the secondary while load
is on n get separated at low load ..or no load

Is This Answer Correct ?    5 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

explain the mode of metal iranafer in Co,welding

1641


if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.

1659


why we use the 100% and 95% stator earth fault protection for the synchronus generator ?

2345


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2296


sir pls send the je exam - 2008 and other model question papers..

2120


why we testing the core balance of the transformer before comissioning?

2217


How to Calculate the Fault Level of Electrical Installation

2313


Explain thin film resistors and wire-wound resistors

1079


Why the efficiency of a three-phase induction is the motor is less than that of a three-phase transformer?

1185


why the neutral line is not giving shock to us if we touch it ?

1843


Explain what are inter-poles and why they are required in a dc machine.

1144


What is the function of RCBO? What are the different sensitivity ratings & each application?

2880


What is the physical significance of phase.. i.e. what is exactly the meaning in layman's language.. 1 phase, 3 phase etc ???

2238


is that any software calculator to calculate the size of cable

2398


Draw the circuit of clapp oscillator?

1191