What happens with squirrel induction machines if the ends
of rotor conductors are kept open? Explain
Answer Posted / sunil guru
if the circuit is complete current flows completely and
more flux is produced so EMF thus torque is produced.....
and if the rotor conductors are kept open then torque cant
be produced without torque rotor cant run....
Is This Answer Correct ? | 7 Yes | 2 No |
Post New Answer View All Answers
What happen when neutral point connected to core balance current transformer? (Neutral point of an alternator of a 180KVA DG. Neutral point connected to CBCT means enter to the CBCT)
RESPECCTED SIR/MADAM- I AM PRERING FOR SECTION ENGINEER (ELECTRICAL) RRB CHANDIGARH PLEASE SEND ME SOME PREVIOUS YEAR QUESTION PAPER OR MODEL PAPER.MY EXAM IS ON (30- NOVEMBER 2008).I AM VERY THANKFUL TO YOU. FROM- HARENDRA SINGH YADAV
How to Design green buildings services? What is the advantage to design green building?
How to check the LM324 Ic
What is the Difference between Ac Drives and Dc Drives? According to application, speed, Torque, cost, Reliability, Construction, Motor etc... Thankyou !!!
i want to apper for apgenco or aptransco or related can any one sugest me where can i get previous papers of thouse exams
Briefing the effects of ASR and ACR of a double closed-loop speed regulating system.
Can anybody post questions asked in Engineers India Limited Interview? Thanks in advance.
Define transfer function?
What is T’Q and X’Q and X’D ? and what is saturated as well as unsaturated ?
What is the necessary and sufficient condition for stability.
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
what is formula for calculate thermal overload in new numiricalrelay( not in bimetal relay)?
why do you add the load short circuit impedance when considering short circuit amperage. It seems that you should only consider supply. If you need to consider loads and you don't know what loads are to be added , what would be a good sub-transient reactance rating for the loads?