Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is intools software

Answer Posted / amit dhavan

The INtools is the instrumentation design and engineering
software.It suite includes integrated modules for
instrument indexes, specifications, process data,
calculation, wiring, loop drawings, hook-ups, calibration
and maintenance...

Is This Answer Correct ?    98 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Hi, Is there any smart plant instrumentation design training institute in Bangalore?

1672


How to Calibrate Coriolis Flow transmitter in field

1266


Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .

2500


what is function of sensor, and how is it work , explain with difination

2382


Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72

2211


What is 1:1 redundancy ?

2383


how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744

2393


How to interfacing microcontroller with a DC motor

2058


How we calculate orifice plat size???

1530


What is the difference between working pressure and calibration pressure of a control valve

3069


What are the different types of thermistors used in industries? How to the operation of typical thermistor?

1965


What is the principle of capacitance type level transmitter?

1079


Programmable Logic control.

1959


Instrumentation Safe Guarding test. How to determine the interval time of the test. eg:Halfyearly,Every year,Every three years etc.

2118


How to work temperature gauge?

1874