Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between Pressure Safety Valve and
Pressure Relieve Valve, in what condition we prefer choose
Pressure Safety Valve rather than Pressure Relieve Valve?
and vice versa

Answer Posted / abhishekk

pressure safety valve is automatic relieves the static
pressure on a gas..usually it opens completelly ..while
relief valve relieve the static pressure in a liquid filled
,its opens proportionally with increasing pressure...
PSV is used in case of gas and PRV is used in liquid.

Is This Answer Correct ?    29 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Draw a group of instruments interlocked to a Pump & Motor?

1338


How hart protocol can be connected with control valves?

1104


Manipulation of dead wt. tester double piston type.

2111


how to convert cubic metre per hour to newton cubic metre per hour

2051


what can of fault ofently come in vibration mesurement?

2191


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1986


what is the field bus calble ? what are diffrences in orang colur cable and black coular calble ?

3091


use of split range ? where it is used ? in which control loop it is used ?

2011


Where Can i take a SPI INtools training in Mumbai? In Rolta India Ltd to whom I should approach regarding of SPI INtools Training?

2825


What is 1:1 redundancy ?

2442


Give 2 application of quartz crystal used for process parameter measurement.

2053


please tell me what is a light up procedure of Cfbc boiler and what it's axuillaries of cfbc boiler?

8728


How earthing can be checked????

2451


how to calibrate and troubleshooting of leveltroll?

2245


how to control pid

1969