what is different between synchronous & asynchronous motors
Answer Posted / sunil guru
SYNCHRONOUS MOTOR
THIS MOTOR ROTATES AT SYNCHRONOUS SPEED AND NOT DEPENDENT
ON LOAD,
BY CHANGING THE EXCITATION OF THIS MOTOR P.F CAN BE MADE
LEADING OR LAGGING.
IT IS ALSO CALLED AS DOUBLY SILENT MOTOR BECAUSE IT RUNS ON
BOTH AC AND DC(FOR STARTING DC IS REQUIRED THEN NOT
REQUIRED)AND THE MOTOR IS NOT A SELF STARTING MOTOR.....
FOR STARTING IT REQUIRES DAMPER WINDING
ASYNCHRONOUS MOTOR
THIS MOTOR ALWAYS ROTATES AT A SPEED LESS THAN SYNCHRONOUS
SPEED
AND SPEED CHANGES DUE TO LOAD AT START THEN BECOME LIKE
CONSTANT
ONLY WORKS ON AC SUPPLY
THIS MOTOR IS SELF STARTING.
AND ALWAYS RUNS ON LAGGING POWER FACTOR
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
HOW TO CALCULATE THE VT SIZING?
Dry type transformers
What happens if we connect a single phase energy meter in reverse polarity.
Can Anyone suggest the Standards (IEC or IS) for selecting copper current density?
what purpose to use excaiter in DG.?
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
hi frnds can any one help me ? plz send me placement paper of IOCL of Electrical streem .... plz send ....its urgent....
How to decide the size of the capacitor for a single phase induction motor say 2 HP ??
what is formula to cal cute earth pit numbers and size of earth strip used in earthing?
how to calculation increase power factor for single phase
how to measure the transformer resistance values(dyn11)?and howmuch the minimum value?
Can i use the B-curve MCB instead of C-curve MCB
What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?
We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me.......
how we can do the insulation on secondary of ct explain and so that tan delta will within limit