Answer Posted / roopakc97
bBeing physical conditions remains constant the current
flowing through the conductor is directly proportional to
the applied voltage and inversely proportional to the
resistance of the conductor.
i,e...I=V/R
Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
i want bhel placement paper for electrical if anybody having pl send to my id kavitha867@myway.com immediately
EHV current carrying parts need to have smooth finish,then how can a 245kv GIS with emery finish can run so long?
is it possible to say motor horsepower number without seeing name plate(when name plate damaged)
What's the difference between non break power supply and non break non short break power supply
All the socket in a room become very hot, the Wall was also became very hot and the earth conductor also became live, what in your view might be the possible causes?
How is the speed of a DC shunt motor related to the armature current?
why to use freewheeling diode ( diode in revers bias mode) across dc coil
how the characterstics of control valve being done
why transformer tank is in rectangular shape what happen when it is in step shape
hi everybody how to design string combiner box (scb) internal parameters like bus bar and spd (surge protection device and fuse which place to set that,and also bus bar one particular cross sectional how much heat generated and how much power loss tell me Clearly and briefly
in control panel, how can i measuring the distance between one bus bar to another bus bar. then now only for bus bar. in mpcb and contactor also. that means one mpcb to another mpcb how much distance? how can i calculate that.
What is the end effect of linear induction motor ??
in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com
Draw the DOL starter and star delta starter drawing?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<