CARGO--cold rolled grain oriented is used as a core of
x'mer it reduces the cu loss,iron loss,low hysteresis loss
ie. magnetization and demagnetization losses ,increases
permeability,and it reduces the excitation current required
to maintain the flux level and therefore increases the
magnetic strength of x'mer........
for any disagreement reply me on parmar20072008@yahoo.com
Is This Answer Correct ? | 18 Yes | 1 No |
Post New Answer View All Answers
what are the usual topology of transformers at different substations in the power system and why that particular topology is choosen. what are the limitaions of that topology?
how to read idmt curva
can we synchronize star system generators with delta system transmission line ? and how ?
What is relation between transmission lines & Communication lines ?
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
State any two nuclear power stations in India, with their generating capacity.
What are the insulation standerds for eg H clase and how many insulation standerds are there and its standerds??????
What is the fault or needs to be done when frequency in ac drives is not changing?
Where is servomechanism used?
What is the maximum No. of out going mccbs permitted from an LV distribution paqnel? What is the ampere relation between incomer and out going switch gears/mccbs?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
Can the output voltage of a rectifier be greater than the input AC voltage without the use of any voltage multiplier in the circuit??please provide the explanation too..
What are the different types of controllers?
Electrical 'C' license full abbreviation , and full form
How to Prepare preventive maintenance shedule of machine tool.