what is the function of CRGO in a Transformer?

Answer Posted / sunil parmar

CARGO--cold rolled grain oriented is used as a core of
x'mer it reduces the cu loss,iron loss,low hysteresis loss
ie. magnetization and demagnetization losses ,increases
permeability,and it reduces the excitation current required
to maintain the flux level and therefore increases the
magnetic strength of x'mer........

for any disagreement reply me on parmar20072008@yahoo.com

Is This Answer Correct ?    18 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the usual topology of transformers at different substations in the power system and why that particular topology is choosen. what are the limitaions of that topology?

1614


how to read idmt curva

1718


can we synchronize star system generators with delta system transmission line ? and how ?

2313


What is relation between transmission lines & Communication lines ?

1698


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1103






State any two nuclear power stations in India, with their generating capacity.

1396


What are the insulation standerds for eg H clase and how many insulation standerds are there and its standerds??????

1489


What is the fault or needs to be done when frequency in ac drives is not changing?

1208


Where is servomechanism used?

663


What is the maximum No. of out going mccbs permitted from an LV distribution paqnel? What is the ampere relation between incomer and out going switch gears/mccbs?

1469


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1657


Can the output voltage of a rectifier be greater than the input AC voltage without the use of any voltage multiplier in the circuit??please provide the explanation too..

1649


What are the different types of controllers?

650


Electrical 'C' license full abbreviation , and full form

1335


How to Prepare preventive maintenance shedule of machine tool.

1523