Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what will happen when a electric bulb is connected between
two phases.it will glow or not

Answer Posted / bk

The bulb rated for 220 [Max 240V] Volts, to be connected
between phase
and neutral. If it is connected between two phases the bulb
is subjected to root3 times 220volts and will get fused.
It can glow if Phase voltage below 150V each.

Is This Answer Correct ?    12 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the types of piano switches?

1982


What the main causes of transient interruptions on Over-Head Distribution Lines?

2055


Does magnetomonopoles exists? one maxwell equation strongly suggests no, but how about their existance in plasma?

1950


What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning

1942


What is critical disruptive voltage?

1271


Ratings of power transformer,Distribution transformer.

1556


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1973


why dimmerstate always connected in star connection? what will happen if it connected in delta?

2004


Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you

1664


why swityard is necessrry requirement in any bis power distributin systems?

2318


I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)

1837


what is the difference between 2 way and 4 pole selector switch???

2370


how to calculate voltage drop and followed by cable calculation?is there avail in formula?

1995


what is doubling factor in making current of a breaker?

2009


why we can use 1 to 5V dc

1906