Answer Posted / abhijeet
Tan delta is test carried out to check the insulation
proprties. it is nothing but the ratio of watt loss to
reactive power. insulation is a capacitor in series with
resistor. if we plot the phasor of Ir and Ic, we get delta
angle between Ieq and Ic. this angle should be as close as
to zero. as angle increases, the insulation properties gets
damaged and will conduct the current as in resistors.
| Is This Answer Correct ? | 14 Yes | 1 No |
Post New Answer View All Answers
draw the full wave and half wave circuit of 3 phase system and inverter circuit used in upsĀ
Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.
what is the difference between active power and reactive power and apparant power in practical as well as theoritical
What is Instantaneous Earth fault relay,how will work
What is Harmonics how it is produced and what is the method to control the same
What is the magnetic field (coil DC ) of Turbo Expander?
Why does increasing the magnetic flux in the main field of a d.c motor cause the armature current to reduce??
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
How can we increase fuel-power ratio of any DG set?
HOW CAN YOU CALCULATE PRACTICAL EFFICIENCY OF A ASYNCHRONOUS INDUCTIONMOTOR OF 7.5KW,& MOTOR IS RUNNING WITH AVOLTAGE OF 410 VOLTS,& TAKING CURENT OF 13 AMPS
which type of questions asking for solar companies?
What is the types of HT motor testing
What is resistance of 50meters, 16sq.mm, single core copper cable?
What is the formula to calculate the no load current of a single & three phase induction motor
How do we calculate the Out put voltage of generator, after the excitation is being given?