How to dimensioning SDCCH, LAPD and CS7 signaling on GSM?
Answer Posted / samridhi singla
different signaling protocols are used between different
signaling nodes. Between mobile station and BTS LADPm
signaling is used . Between BTS and BSC LADP signaling is
used.Between BSC and MSC SS7 signaling is used. Signaling is
required to communicate the necessarily distributed function
entities of the network
| Is This Answer Correct ? | 13 Yes | 4 No |
Post New Answer View All Answers
Who many reason of ignition fail ?
How to set a Zone 1 distance relay for distribution feeder?
wat is the current produced in a 5000v megger? when the positive and negetive terminals are touched on our body get s shock?
what is gridrotor resistance starter
Define what is difference between fuse and breaker?
can any one provide me a connection wiring diagram for a DG set control panel along with BOM?
what is the difference between ups & inverter
Type of motor stater detail and working detail
How will you justify IR value and Charging voltage of any motor,transformer and Cables.......???? . . . . . . . . Plz tell me any body Baljeet Singh, engineer_89@refiff.com
what you have to see after one week or month from the day of installation of transformer ?
when measure the core loss of three phase distribution transformer or three phase reactor loss, one phase shown negative watt loss. why??
what are the factors to be considered while design the breaker either HT or LT??
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
How can claculate to attain the desired PF in the line ( HOW Much KVAR is required ) Pls Give the formula? Equate Petrochemical 0 1 how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec. 0 1 What will happened. if we feed 3phase supplay to the stater with out insert the rotor. How much current will flow through the stater winnding? Equate Petrochemical 0 1 What is required of exietation to the alternater. 0 1 why star point of HT motor not earthed? Equate Petrochemical 0 1 Why we are getting low voltage in star connection? Equate Petrochemical 0 2 What's ND relay & it's functions? Equate Petrochemical 0 2 How instantanious short circuit current is calculated? its formula? Equate Petrochemical 0 2 What is servo Motor? What's the advantages of this motor over Induction motor? Equate Petrochemical 0 2 What is core CT & it's function? Equate Petrochemical 0 3 what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY L & T 0 4 What is required of exietation to the alternater. KNB 1 23 what is the design voltage for 6.6KV 2000 KVAR HT capacitor? Consultancy 0 3 Pls explain about vfd control?Where it is used, Give some example? siemens 1 22 Please explain me abt PQ diagaram in the power sector. 0 9
How many double suspension hardware fittings are required on a double circuit transmission tower?