why dc power can not be used in transformer?
Answer Posted / manikandan
Dc supply can be fed to the transformer ..but it should be
fed slowly however there ll not be any change in the o/p
since there is no path for flux the windings ll not
burn..but in competitive exam if these type of q uestion
asked means answer the winding ll burn...
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
what is the formula of starting current of 3phase and 1 phase motor???
what is a synchronizing lamp ?
1.what is the reason for transformer and lightning arrester blast in 33kv system
if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit
I HAVE A 50A MCCB AS PER DESIGN LINE WIRE CONNECT UPWORD SIDE AND LOAD IS CONNECTED TO DOWNWARD SIDE TO THE MCCB.IF NOW ANY ONE CHANGE SUPPLY & LOAD(WISEVERSA) WHAT HAPPENS ? DOES MCCB OPERATION OR WORKING FUNCTION NORMAL IF YES THAN WHY THERE ARE MARKED LINE & LOAD ON MCCB.
pls,send the previous year written test questions.
Why LED light has advantage of rapid reflection ,although other lights alse reflect.? and this light is considered to be best for transmission usage in case of Free optics
Which type of transformer is used for lighting loads?
mccb service sittings be done?
sir vizag steel ka junior trainee ka paper kitne number ka ayega
What is resistance of 50meters, 16sq.mm, single core copper cable?
What is dc current source? Differentiate between ideal and non ideal current sources?
why servomotor motor? where i apply for best output?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
How many points does a Circuit can have?