I need to compare the energy consumption of an industrial
machine before and after improving. Shall I compare the
apparent power or the active power? I know usually
factories use compensated capacitors (or other similar
components) to compensate the reactive power, so if I use
the apparent power, it's not the real power consumed.
Answer Posted / ullas
by connecting a capacitor bank to any inductive load meets
the reactive power demand. since the KVAR portion changes
the KVA portion also changes and KW portion remains i its
original position. since the factories are charged by the
electricity suppliers by considering in to their power
factor. whe we are having a low powerfactor, then reactive
demand is higher. so to meet this capacitors are used to
meet the reactive demand.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
list the type of vfd? wich is sutable for heating kiln?
use of choke in APFC panels
Why does the Solid state Rectifiers for 3-ph brake motors sometimes have 2 & sometimes 3 output terminals?
sir, 3phase induction motor takes different pf and different KW in three phase while running,explain reason
The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.
What is the actual calculation for transformer short circuit test?.
What is the main use of rotary phase converter ?
Phase control and integral control are used for?
As an electrical engineer what are the responsibilities which i can hold in TCS?
Difference between drift current and diffusion current?
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
Dg pf .71 i am improve pf 0.80 what capacitor connected in dg how?
Should power factor be low or high?
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
What are the types of transformers according to the arrangement of iron cores?