Why Instrumentation Air Compressor called as
Instrumentation Air compressor?pls dont just tell its
trasferring IA to all transmitter,valves.I need exact
reason, please......................

Answer Posted / abhishek vyas

Basically in organization there diffrent pressure required
say 6kg/cm. sq. to 16 kg/cm.sq. for diffrent purpose so
utility area has configure their compressore as per
pressure required ,6kg/cm.sq pressure is the basic
requirement for control valve,actuator etc so that
compressore is called instrument air compressore which is
producig 7.0 kg./cm. sq. taking the fact in considaration
of Air savig and power saving.

Is This Answer Correct ?    2 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Which tank weighing system is better to install (Accuracy point of view) 1) Tank weighing system with 3 load cell or 2) Tank weighing system with 4 Load cell

734


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

1619


Capacitance, resistance ( colour coding ), parallel & series circuits.

1725


How an rtd work, and what volts/current goes to a rtd to measure the resistance?

723


what is the difference between active & reactive power?

1657






I have 0.75mm sq multicore cable (IS type) , can use instead of same type but 1.5 sq mm cable ? Note : The distance is around about 150 meter.

1151


what is the procedure of belt scale calibration?

1962


sir, give me placement papers and interview quistion of birla group company of copper.

2365


what is function of sensor, and how is it work , explain with difination

1880


What is stripper & spilitter ? Diffrence in this.?

2526


Why plc require in analog input 4-20amp & 0-10 volt?

619


What is the cascade control

984


how u calibrate pneumatic n motorized c/v?

1524


in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.

2281


What are the interlocks we have to check during the start up of LP/HP compressor?

1481