WHY WE NOT USE 2-20mA,1-20mA,3-20mA or 10-50mA SIGNAL?
INSTEAD OF 4-20mA.
Answer Posted / anil
starting with 4ma is to know DEAD or LIVE of the
transmitter,4 to 20 is used for linearty and according to
ohms law to covert 1 to 5 volt dc,
| Is This Answer Correct ? | 19 Yes | 4 No |
Post New Answer View All Answers
What is standard procedure of manual mapping in Radar type level transmitter?
How to control flow variations in magnetic flow maters..... When i will provide proper earthing?
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
How does temperature bath work? How does coil gets heated only by applying some current?
How is PH sensor works ?
i am preparing for BARC ,so plz mail me how to prepare for BARC. ALSO IF POSIBLE SOME RELATED QUESTIONS. MY MAIL ID IS khushi_4uall2003@yahoo.co.in
1. what is modbus cable? 2. what kind of communication we are using for the interface of DCS, ESD and Third party cabinets? 3. What is serial communication and peer to peer communication?
Displace type LT to be calibrated in workshop, wt. 40, dia- 60 mm, density- 0.8kg/cm3.
DEAR SIR/MADAM MY NAME IS ARKAPROVA BHATTACHARYYA.I AM A FRESHER INSTRUMENTATION ENGINEER.CAN YOU PLEASE SEND SOME QUESTION PAPERS OF GRADUATE ENGINEER TRAINEE EXAM OF DVC(DAMODAR VALLY CORPORATION).MY EMAIL IDs ARE arka_aec@rediffmail.com.
What is the function of solenoid valve in on/off & shutdown valve and why it is not used in control valve normally?
diff between neutral ,ground,phase , earthing and shielding?
I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.
Why is it necessary to use compensation leg to measure the liquid level in a closed or pressurized tank?
There are many type of control cable like pair,core,tried, What are defination each one
what will the sending unit in the fuel gauge utilizes?