Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I have connected 04nos. earthings to a transformer through
04nos. earthing pits seperately. 02nos. earthings are
connected to T/F body, and 02nos. earthings are connected to
T/F neutral.T/F capacity is 2000KVA, 11KV/415V. But after
completing of 02 years successful operation ,we are
facing following problems-

1. CT/PT occured blast one time
2. HT cable box occured blast two times
3. One body earthing strip and one neutral earthing strip of
transformer are overlapping at some places. Whenever these
two strips are pressed at overlapped points, they made spark.

What is the reason of spark?

Please explain the reason & rectification of above problems

Answer Posted / santosh kawade

Please contact me Santosh 9224 69 3116,

Probably site inspection require to sortout your problem.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the safty of poly phase tranformer?

2068


On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?

4309


Hi,iam a diploma in electrical engineering.rtd from indian air force in apr 2007.prsently working in reliance next link as a network maintenance engineer since 2007,can i get a job in motherson sumi.

2316


what are the things that can cause a three phase motor to crawl?

3473


if we have a industrial load of 400 kilowatts with 415 volt AC then how much total harmonic distortion (thd%) should be acceptable for steady power system.

1936


A jet of fluid strikes a plate What was the force required to counter it?

1825


what is the circulate the diesel in DG in side pls tell parts name and picture with circulate the diesel

1940


how to apply b license to c license in tneb

1771


what is sevice settings for mccb?How can be it setted?

2133


WHY NUTRAL GROUND SYSTEM USED IN 33KV SYSTEM

2173


How to measure size of cable on a given load

1777


what is the difference between earthing and unearth

2964


why Induction Generators are not "Black start" ? and apart from WTGs where this types of generator are generally used?

2595


-How do you select cable size for a given load at a given distance from source of supply. How do you find voltage drop.

1748


If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..

2447