Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHY WE NOT USE 2-20mA,1-20mA,3-20mA or 10-50mA SIGNAL?
INSTEAD OF 4-20mA.

Answer Posted / mike betts

I am not sure why the range of 16mA i.e 20 - 4, but the 4mA
starting is so that you have a posative value of current for
all values that the loop current represents. This way, if
you have no current at all, the loop is open circuit for
some reason.

Is This Answer Correct ?    4 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Draw a great bridge circuit.

2059


how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?

5731


What is stripper & spilitter ? Diffrence in this.?

3067


How to fix back the valve actuator stem

2118


How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)

2649


List three types Level Switches with their working principles

2188


A valve in series with an orifice plate (DP transmitter), is aligned for constant pressure in the pipeline, if there is an error dx, How to align it in process.

1406


Identification of ss fittings, pilot valves, relief valve.

1883


what is interface level measurement.who can calibrate interface level measurement transmitter online

2586


why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.

2795


can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.

2328


How to measure the dust in chimney(spm)?

4147


Describe the typical instrumentation used in monitoring the performance of a shell and tube heat exchanger.

2128


Please any one can provide latest aptitude test,technical test and interview questions for tata consulting engineering (TCE) i need it asap thanks in advance

2077


Full form of KKS when use DCS.

3229